Power supply unit status indicator is unlit
|
Power failure at power outlet, switched outlet is switched off or SERVO-DRIVE power supply unit is not connected to the power outlet
|
Try another electrical item (e.g. a mobile phone charger). If this is not working either, then there is no power supply.
|
Switch on the switched outlet, check the fuses and the residual current circuit breaker (RCD) and contact an electrician if necessary.
|
SERVO-DRIVE power supply unit is defective
|
The SERVO-DRIVE power supply unit is defective if the SERVO-DRIVE power supply unit status indicator does not light up although the socket is active and switched on.
|
Replace the SERVO-DRIVE power supply unit.
|
Status indicator on SERVO-DRIVE flex is unlit
|
SERVO-DRIVE flex is defective
|
SERVO-DRIVE flex is defective if the SERVO-DRIVE flex status indicator is not lit when the front is open, despite correct cabling.
|
Replace SERVO-DRIVE flex.
|
SERVO-DRIVE flex does not respond or does not always respond to opening request, reset or reference run
|
Transport aids on the white goods have not been removed
|
|
Remove the transport aids on the white goods in accordance with the instructions provided for the white goods.
|
Rigid bumper elements mounted instead of sprung Blum distance bumpers or sprung Blum distance bumpers stiff
|
The bumper elements installed are either too stiff, or if they do not depress when pressed with a finger, are not sprung Blum distance bumpers.
|
Replace the rigid bumper elements with sprung Blum distance bumpers or replace the sprung Blum distance bumpers if they are resistant to moving.
|
Number of sprung Blum distance bumpers is incorrect or their assembly position is unsuitable
|
The assembly positions of the sprung Blum distance bumpers are incorrect if they differ from the quantity or the planning information provided in the catalogue .
|
Have the quantity or the assembly position of the sprung Blum distance bumpers corrected by the distributor's customer service department.
|
Front gap not set correctly
|
The front gap is not set correctly if at least one of the sprung Blum distance bumpers is pressed in when the front is closed or is not in contact with the cabinet.
|
Have the front gap corrected by the distributor's customer service department.
|
SERVO-DRIVE flex rod is incorrectly positioned against the front
|
The SERVO-DRIVE flex rod is incorrectly positioned against the front if it is insufficiently pressed in when manually closing the front.
|
Have the depth position of the SERVO-DRIVE flex adjusted in accordance with the planning information provided in the catalogue or have the front adjusted by the distributor's customer service department. Subsequently start the reference run manually as described in the installation instructions .
|
Front too soft or unstable, sealing lip too hard, or too many sprung Blum distance bumpers installed
|
If the front gap at the height of SERVO-DRIVE flex does not change or barely changes while pressing on the front at different points, the front is too soft or unstable, the sealing lip on the white goods is too hard, or too many sprung Blum distance bumpers have been installed.
|
Have the SERVO-DRIVE switch installed by the distributor's customer service department and connect it to SERVO-DRIVE flex.
|
Rod rubbing against the front drilling
|
The rod is rubbing against the front drilling if the friction is clearly discernible when the front is opened by moving the rod manually.
|
Have the position of the front drilling for the SERVO-DRIVE flex rod corrected by the distributor's customer service department in accordance with the planning information provided in the catalogue . Subsequently start the reference run manually as described in the installation instructions .
|
Vacuum in the refrigerator is too high
|
The vacuum in the refrigerator is too high if it cannot easily be opened again, shortly after it has been open for a longer period of time (e.g. when putting items away or cleaning).
|
Wait up to 20 seconds until the vacuum has automatically reduced.
|
Opening angle insufficient
|
Reference run not performed correctly
|
The reference run was not performed correctly if the refrigerator was not cold at this time or there was manual intervention by the user.
|
Manually start the SERVO-DRIVE flex reference run in accordance with the installation instructions.
|
|
Catch plate not mounted on the front or mounted in the wrong position
|
The catch plate is incorrectly positioned on the front if the rod does not meet it in the centre.
|
Have the catch plate installed, or its assembly position corrected by the distributor's customer service department.
|
Something inside the refrigerator or dishwasher has collided with the front
|
|
|
|
SERVO-DRIVE flex is loose if the side mounting plate has been insufficiently screwed on, or if the additional front screw is missing or has been inserted on the wrong side.
|
Have the type of SERVO-DRIVE flex installation adjusted by the distributor's customer service department in accordance with the planning information provided in the catalogue . Subsequently start the reference run manually as described in the installation instructions .
|
Dishwasher locking mechanism is stiff
|
|
This is not a SERVO-DRIVE flex fault.
|